Stainless-Steel-Filters
The MicraSteel filter housings can be used in a variety of applications including:
- Filtration of high purity bottled gas
- Filtration of liquid or gas samples to process analysers
- High Pressure or vacuum Filtration
- Filtration of gases to sterile level
- Protection of precision in-line valves and equipment
- Liquid or gas sample Filtration with minimum response time
MicraSteel Filter housings haue been designed for high efficiency Filtration of gases and liquids in critical applications. The range of polished AIS1316L stainless steel Filter housings are purpose designed for use with all grades of MicraTube, MicraLescer or MicraMesh Filter tubes. Manufactured from solid steel bar stock, in accordance with NACE MR-01-75 specification, they can be used in the pressure range from full vacuum to 350 barg (5000 psig).
MicraSteel Filter housings haue been designed for ease of Operation, with a small internal volume to keep response times to a minimum in analyser applications. The three types of filter tube available provide different performance characteristics for a number of installations. MicraTube offers particulate removal at various micron efficiencies. MicraLescer is a coalescing element which removes oil aerosols and particulate matter. MicraMesh is a stainless steel, precision woven, mesh filter, offering bulk contaminant removal.
MicraSteel housings are manufactured to fine tolerances and each Filter tube is held securely in place by a precision machined centre core and locknut. No special tools are required to replace the internal Filter tube or to undo and refft the filter bowl making inspection and filter tube replacement MicraSteel Filter housings can be ordered in alternative materials such as Monel or Hastelloy for applications that require a higher level of resistance to aggressive gases and liquids. If required, MicraSteel can be factory prepared for use in Oxygen rich environments at extra cost. Standard pipe connections are NPT.
|
|
|
| Model |
Pipe size NPT |
Flow rate Nm3/h SCFM |
Dimensions in mm |
Housing weight (kg) |
Tube size (mm) |
| |
|
|
A |
B |
C |
D |
|
|
| 350 barg (5000 psig) maximum operating Pressure |
| cmc-351-1232-[]-* |
1/8 |
8.5 |
5 |
41 |
10 |
78 |
35 |
0.4 |
12 x 32 |
| cmc-352-1232-[]-* |
1/4 |
11 |
6 |
41 |
10 |
78 |
35 |
0.4 |
12 x 32 |
| cmc-351-1257-[]-* |
1/8 |
12 |
7 |
41 |
10 |
103 |
60 |
0.45 |
12 x 57 |
| cmc-352-1257-[]-* |
1/4 |
29 |
17 |
41 |
10 |
103 |
60 |
0.45 |
12 x 57 |
| cmc-354-2564-[]-* |
1/2 |
60 |
35 |
65 |
20 |
135 |
70 |
1.9 |
25 x 64 |
| 100 barg (1500 psig) maximum operating Pressure |
| cmc-102-2564-[]-* |
1/4 |
29 |
17 |
65 |
20 |
135 |
70 |
1.9 |
25 x 64 |
| cmc-104-2564-[]-* |
1/2 |
60 |
35 |
65 |
20 |
135 |
70 |
1.9 |
25 x 64 |
| cmc-102-2178-[]-* |
1/4 |
34 |
20 |
65 |
20 |
250 |
180 |
2.8 |
25 x 178 |
| cmc-104-2178-[]-* |
1/2 |
90 |
53 |
65 |
20 |
250 |
180 |
2.8 |
25 x 178 |
| Operating Pressure |
barg |
1 |
2 |
4 |
7 |
10 |
15 |
20 |
50 |
100 |
150 |
250 |
350 |
| |
psig |
15 |
30 |
60 |
100 |
150 |
200 |
300 |
750 |
1500 |
2000 |
3500 |
5000 |
| Correction factor |
|
0.3 |
0.5 |
0.75 |
1 |
1.2 |
1.5 |
1.7 |
2.5 |
3.5 |
4.5 |
6 |
7 |
|
|
|
* For MicraSteel housings with a drain connection include suffix [D]. MicraSteel housings with PTFE seals [F] or [FDJ Correction factor: for maximum flow rate, multiply model flow rate shown in the above by the correction factor closest to the actual working Pressure.
|